Experimental Study of RC Hollow Beams with Embedded PVC Pipes
DOI:
https://doi.org/10.30659/jacee.5.1.11-23Keywords:
Hollow section, Longitudinal void, PVC pipe, Reinforced concrete beamAbstract
This study investigated the behaviour of reinforced concrete (RC) hollow beams under incremental static loads. Polyvinyl Chloride (PVC) pipes were used to create longitudinal voids in hollow beams. The parameters studied included the size (25 mm, 50 mm and 75 mm diameter) and location (39 mm and 139 mm from beam soffit) of the PVC pipes in the beam. Nine specimens were tested under the four-point load test setup. The loads were progressively increased until the specimens failed. The specimens were analysed based on the failure modes, load-displacement responses and mechanical properties. The hollow beams gave a 2% to 36% lower strength than the solid beams. In terms of the strength per unit concrete, the hollow beams were less efficient than the solid beams. The efficiency ratio of hollow beams ranged from 0.67 to 1.0. For that, none of the proposed hollow beams was recommended.Downloads
Published
Issue
Section
License
The copyright of the received article shall be assigned to the journal as the publisher of the journal. The intended copyright includes the right to publish the article in various forms (including reprints). The journal maintains the publishing rights to the published articles.

This work is licensed under a Creative Commons Attribution 4.0 International License.